Description: Toner hopper error (yellow process unit) • When yellow toner is replenished (simple replenishment), if the replenishment release level is not reached even if yellow toner is replenished for 3 s (1 s) with the yellow toner low level not detected, the state is regarded as a yellow toner container non-installing error. This error occurs four times.
Causes: Yellow toner container is not installed. Defective engine controller PWB.
Remedy: Yellow toner container is not installed. Check the state of the yellow toner container and install it properly. Defective engine controller PWB. Replace the engine controller PWB.