Code: C0000
Description: Main Motor’s failure to turn
The Main Motor Lock signal remains faulty for a predetermined continuous period of time while the Main Motor is turning.
The Main Motor Lock signal remains faulty for a predetermined continuous period of time while the Main Motor is turning.
Remedy: 1 Main Motor turns when the Start key is pressed. NO: Check connector for connection. Correct drive coupling (drive transmitting gear engagement). 2 Main Motor rotation when the Start key is pressed: the voltage across PJ13I-7A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change Master Board. 3 Main Motor rotation when the Start key is pressed: the voltage across PJ7PU1-4 on DC Power Supply 1 and GND is DC 0 V when the motor is deenergized and DC 24 V when the motor is energized. NO: Change DC Power Supply 1.