Mã lỗi C004C — Kyocera KMC3130

Code: C004C

Description: Ozone Ventilation Fan Motor’s failure to turn
An Ozone Fan Lock signal is detected for a continuous 3-sec. period while the Ozone Ventilation Fan Motor is turning.
Remedy: 1 Ozone Ventilation Fan Motor turns when the Start key is pressed. NO: Check connector for connection. Check fan for overload. 2 Ozone Ventilation Fan Motor rotation when the Start key is pressed: the voltage across PJ10I-15 on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. NO: Change Master Board. 3 Ozone Ventilation Fan Motor rotation when the Start key is pressed: the voltage across CN2HV3-3 on High Voltage Unit 3 and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change High Voltage Unit 3.