Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C0060 — Kyocera KMC3130

Code: C0060

Description: Fusing Drive Motor’s failure to turn
A Fusing Drive Motor Lock signal remains faulty for a predetermined continuous period of time while the Fusing Drive Motor is turning.
Remedy: 1 Fusing Drive Motor turns when the Start key is pressed. NO: Check connector for connection. Correct drive coupling (drive transmitting gear engagement). 2 Fusing Drive Motor rotation when the Start key is pressed: the voltage across PJ13I-1A on Master Board and GND is DC 5 V when the motor is deenergized and DC 0 V when the motor is energized. YES: Change motor. NO: Change Master Board. 3 Fusing Drive Motor rotation when the Start key is pressed: the voltage across PJ7PU1- 4 on DC Power Supply 1 and GND is DC 0 V when the motor is deenergized and DC 24 V when the motor is energized. NO Change DC Power Supply 1.

← Xem tất cả mã lỗi Kyocera KMC3130