Code: C0098
Description: Fusing Roller pressure/ retraction failure
• No change is observed in the encoder pulse even after the lapse of 0.5 sec. after the Fusing Pressure/Retraction Motor has started turning for retraction direction during retraction control. • No change is observed in the encoder pulse even after the lapse of 0.5 sec. after the Fusing Pressure/Retraction Motor has started turning for pressure direction during pressure control. • The Fusing Pressure Position Sensor is not activated (pressed position) even when 31 motor encoder pulses have been counted after the Fusing Pressure/Retraction Motor has started turning for pressure direction during pressure control.
• No change is observed in the encoder pulse even after the lapse of 0.5 sec. after the Fusing Pressure/Retraction Motor has started turning for retraction direction during retraction control. • No change is observed in the encoder pulse even after the lapse of 0.5 sec. after the Fusing Pressure/Retraction Motor has started turning for pressure direction during pressure control. • The Fusing Pressure Position Sensor is not activated (pressed position) even when 31 motor encoder pulses have been counted after the Fusing Pressure/Retraction Motor has started turning for pressure direction during pressure control.
Remedy: 1 Fusing Pressure/Retraction Motor rotation when the Fusing Roller is retracted: the voltage across PJ14I-4A on Master Board and GND is DC 0 V when the motor is deenergized and DC 24 V when the motor is energized. YES: Check motor connector for connection. Change motor. NO: Change Master Board. 2 I/O check for Fusing Pressure Position Sensor when the Fusing Roller is retracted: the voltage across PJ6I-11B on Master Board and GND is DC 0 V when the sensor is unblocked (retracted position) and DC 5 V when the sensor is blocked. YES: Change Master Board. NO: Check sensor installation. Correct detecting plate. Check sensor connector for connection. Change sensor. 3 Fusing Pressure/Retraction Motor rotation when the Fusing Roller is pressed: the voltage across PJ14I-5A on Master Board and GND is DC 0 V when the motor is deenergized and DC 24 V when the motor is energized. NO: Change Master Board. 4 I/O check for Fusing Pressure Position Sensor when the Fusing Roller is pressed: the voltage across PJ6I-11B on Master Board and GND is DC 0 V when the sensor is unblocked and DC 5 V when the sensor is blocked (pressed position). YES: Change Master Board. NO: Check sensor installation. Correct detecting plate. Check sensor connector for connection. Change sensor. 5 I/O check for Fusing Retraction Position Sensor operation while the Fusing Pressure/ Retraction Motor is turning: the voltage across PJ17I-3B on Master Board and GND remains DC 0 V when the sensor is unblocked or remains DC 5 V when the sensor is blocked while the motor remains stationary, and alternates between DC 0 V when the sensor is unblocked and DC 5 V when the sensor is blocked while the motor is turning. YES: Change Master Board. NO: Check sensor installation. Correct detecting plate. Check sensor connector for connection. Change sensor.