Mã lỗi C6000 — Kyocera KMC4035E

Code: C6000

Description: Fuser thermistor 1/3 break error Fuser thermistor 1 detected 40 C/104 F or less during warming up. 40 C/104 F or less is detected between 10 s of continuation during worming up. Fuser thermistor 3 detected 40 C/104 F or less during warming up.
Causes: Defective fuser heater 1/2. Defective fuser thermostat 1. Installation defectiveness on fuser thermistor 1/2. Defective PWB.
Remedy: Defective fuser heater 1/2. Check for continuity across each heater. If none, replace the fuser unit. Defective fuser thermostat 1. Check for continuity across thermostat. If none, remove the cause and replace the fuser unit. Installation defectiveness on fuser thermistor 1/2. Measure the resistance. If it is ∞Ω, replace the fuser unit. Defective PWB. Replace the power source PWB or engine PWB and check for correct operation.