Code: C7000
Description: Toner motor problem The rated speed achievement signal won’t turn to L in 5 s since the motor is activated. The rated speed achievement signal turns to H every other 5 s after the machine is stabilized.
Causes: Poor contact in the connector terminals. Broken the gear. Defective toner motor M/C/Y/BK. Defective engine PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC30 on the engine PWB and the connector on the toner motor, and the continuity across the connector terminals. Repair or replace if necessary. Broken the gear. Check visually and replace the gear if necessary. Defective toner motor M/C/Y/BK. Run maintenance item U135 and check if the toner motor operates. If not, replace the toner motor. Defective engine PWB. Replace the engine PWB and check for correct operation.