Code: C4200
Description: Horizontal synchronized signal (PD) detection error • The horizontal synchronization signal (PD) is not entered by the laser scanner unit when ASIC (U7) on the engine controller PCB has issued a laser activation signal.
Causes: Defective engine controller PCB. Defective laser scanner unit (PD PCB). Defective harness between engine controller PCB and laser scanner unit, or poor contact of the connector terminals.
Remedy: Replace the engine controller PCB and check for correct operation. Replace the laser scanner unit. Check the continuity of the harness and the insertion of connectors.