Description: Communication problem between the scanner main PCB and fax board • The status cannot be normally received even if the fax board has retried command transmission 100 times.
Causes: Poor contact in the connector terminals. Defective scanner main PCB or fax board.
Remedy: Check the connection of connector CN26 on the scanner main PCB and the connector on the fax board. Repair or replace if necessary. Replace the scanner main PCB or fax board and check for correct operation.