Code: C3200
Description: Exposure lamp problem • Check the CCD input value for the lighting status of the exposure lamp 100 ms after the exposure lamp is lit and the carriage is moved to the shading position. If the exposure lamp does not light, turn off the lamp. After 500 ms, light the lamp again and, a further 500 ms later, check the CCD input. The exposure lamp does not light after 5 retries.
Causes: Defective scanner main PCB. Defective exposure lamp or inverter PCB. Incorrect shading position. Poor contact of the connector terminals.
Remedy: Replace the scanner main PCB and check for correct operation. Replace the exposure lamp or inverter PCB. Adjust the position of the contact glass (shading plate). If the problem still occurs, replace the scanner home position switch. Check the connection of connector CN40 on the scanner main PCB, and the continuity across the connector terminals. Repair or replace if necessary.