Code: C0280
Description: Abnormal communication between MMI and fax control PCB • After MMI PCB status change signal turns on 1 minute, when it does not receive key required command from the fax control PCB, one time it resets the FAX. After that, while MMI PCB status change signal turns on furthermore 1 minute, when it does not receive key required command from the fax control PCB. • When FAX_READY signal continues “fake” for 6 s, one time it resets the FAX. After that, when FAX_READY “ fake” continues " fake " for 6 s.
Causes: Poor contact in the connector terminals. Defective scanner main PCB or fax control PCB.
Remedy: Check the connection of connector YC1123 on the scanner main PCB and the connector on the fax control PCB. Repair or replace if necessary. Replace the scanner main PCB or fax control PCB and check for correct operation.