Code:
C5650
Description: Dark potential error Surface potential is still not within the effective range for target potential after surface potential correction is executed 10 times.
Causes: The drum surface potential sensor connector terminals are loosely connected or make poor contact. The drum surface potential sensor is defective. The drum surface potential PCB is defective. The main charger wire is broken. The main charger grid is broken. The main high-voltage transformer connector terminals are loosely connected or are making poor contact. The main high-voltage transformer is defective. The engine main PCB is defective
Remedy: Check for continuity across the connector terminals and remedy if necessary. Replace the drum surface potential sensor and the drum surface potential PCB and check for correct operation. Replace the drum surface potential sensor and the drum surface potential PCB and check for correct operation. Replace the main charger wire. Replace the main charger grid. Reinsert the connector. Also check for continuity across the terminal wire and if none, remedy or replace the wire. Replace the main high-voltage transformer and check for correct operation. Replace the engine main PCB and check for correct operation.