Code: C6000
Description: Broken main fixing heater connection • Machine operation still did not become stable after 20 minutes in ambient temperature of 15C or higher. • Machine operation still did not become stable after 30 minutes in ambient temperature lower than 15C. •Temperature detected by fixing unit thermistor 1 was lower than 100C after fixing stabilized.
Causes: The main fixing heater is not installed correctly. The main fixing heater has a break. Fixing unit thermistor 1 is not installed correctly. Fixing unit thermistor 1 connector terminals are loosely connected. Fixing unit thermistor 1 has a break. The fixing unit thermostat operates. The fixing heater control circuit on the power source PCB is broken. The engine main PCB or the power source PCB is defective.
Remedy: Check and reinstall if necessary. Check for continuity and if none, replace the main fixing heater. Check and reinstall if necessary. Check the connection of CN2-15 on the engine main PCB and continuity across the terminals. If there is abnormality, remedy or replace. Measure the resistance. If the resistance is ∞Ω, replace fixing unit thermistor 1. Check for continuity. If none, replace the fixing unit thermostat. Run maintenance item U196 by selecting “HEAT1”. If voltage between TB3 and CN2-1 on the power source PCB does not become 100 V AC, replace the PCB. Run maintenance item U196 by selecting “HEAT1”. If CN4-8 on the engine main PCB does not go low, replace the engine main PCB or the power source PCB and check for correct operation.