Code: C0210
Description: Communication problem between the main and engine
When the power is turned on, the machine does not detect the low level of SBSY and the high level of SDIR for 10 s.
When the power is turned on, the machine does not detect the low level of SBSY and the high level of SDIR for 10 s.
Causes: Poor contact in the connector terminals.
Defective main/ engine PWB.
Defective main/ engine PWB.
Remedy: Poor contact in the connector terminals. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Defective main/ engine PWB. Replace the main/engine PWB and check for correct operation.
Defective main/ engine PWB. Replace the main/engine PWB and check for correct operation.