Mã lỗi C6050 — Kyocera TASKalfa 181

Code: C6050

Description: Abnormally low fuser thermistor temperature
Fuser thermistor remains below 90°C/ 194°F for 1 s.
Causes: Poor contact in the fuser thermistor connector terminals.
Broken fuser thermistor wire.
Fuser thermistor installed incorrectly.
Fuser thermostat triggered.
Fuser heater installed incorrectly.
Broken fuser heater wire.
Remedy: Poor contact in the fuser thermistor connector terminals. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable.
Broken fuser thermistor wire. Measure the resistance. If it is ∞, replace the fixing thermistor.
Fuser thermistor installed incorrectly. Check and reinstall if necessary.
Fuser thermostat triggered. Check for continuity. If none, replace the fuser thermostat.
Fuser heater installed incorrectly. Check and reinstall if necessary.
Broken fuser heater wire. Check for continuity. If none, replace the fuser heater.