Code: E-0001
Description: Fuser Over Temperature Error
Fuser Temperature reaches over 200C.
Fuser Temperature reaches over 200C.
Remedy: Error clearance 1 Have you cleared the fuser error in the Special Operation Mode? Yes Wait until the Fuser Unit is enough cooled down. Then select the Special Operation Mode and clear the concerning error. Wires 2 Are wires among Lamp (H1), Solid State Relay (SSR1) and Thermistors (TH1 & TH2) connected properly? No Connect them properly. Solid State Relay (SSR1) 3 Does the error occur again even if you have cleared it in the Special Operation Mode? Yes Replace the Solid State Relay. Thermistors (TH1 & TH2) 4 Select the Information Mode, and then check the temperature of fuser detected by Thermistors (TH1 & TH2). Item No. : 00 (Fuser temperature 1) 01 (Fuser temperature 2) Is each temperature normal? No Replace the concerning Thermistor.