Code: E-0003
Description: Fuser Temperature Abnormal Fall Error
The difference of temperature between center and side of fuser becomes 50C or more.
The difference of temperature between center and side of fuser becomes 50C or more.
Remedy: Error clearance 1 Have you cleared the fuser error in the Special Operation Mode? Yes Wait until the Fuser Unit is enough cooled down. Then select the Special Operation Mode and clear the concerning error. Wires 2 Are wires among Lamp (H1), Solid State Relay (SSR1) and Thermistors (TH1 & TH2) connected properly? No Connect them properly. Thermistors (TH1 & TH2) 3 Select the Information Mode, and then check the temperature of fuser detected by Thermistors (TH1 & TH2). Item No. : 00 (Fuser temperature 1) 01 (Fuser temperature 2) Is each temperature normal? No Replace the concerning Thermistor.