Code: E-0010
Description: Main Motor Error
The Main Motor Output Detection Signal (MAINM_LD) continues to be “H” for 3 seconds or longer when the Main Motor is rotating.
The Main Motor Output Detection Signal (MAINM_LD) continues to be “H” for 3 seconds or longer when the Main Motor is rotating.
Remedy: Wires 1 Is the wire between Main Motor and PW11720 PCB connected properly? No Connect it properly. Confirm that the machine is turned on, and then check the voltage of the orange line (J220-5). Is it 24V? No Replace the DC Power Supply if there is no problem with the wires. DC Power Supply (DCP1) or Fuse 2 Confirm that the machine is turned off, and then check whether or not each Fuse is broken. Is any Fuse broken? Yes Replace the Fuse. Main Motor (M1) 3 Check the operation of Main Motor in the Operation Check Mode of the Service Mode. Device Code : 00 (Main Motor) Does the Main Motor operate correctly? No Replace the Main Motor.