Description: Image Corona Output Error
The Image Corona Output Detection Signal (IM_LD) continues to be “L” for 1 second or longer when the Image Corona is ON.
Remedy: Wire 1 Are wires among Image Corona, HV Power Supply PCB and PW11720 PCB connected properly? No Connect them properly. 2 (For Image Corona / Cleaning Roller only) Is the spring on the left bottom of the Process Unit OK? No Correct it properly. Is the Image Corona dirty? Yes Clean each Corona Wire, Grid Plate and housing. Image Corona 3 Is the Corona Wire broken? Yes Replace the Corona Wire. Does the bias terminal plate touch to Cleaning Roller shaft properly? No Remove and reapply conductive grease to Cleaning Roller shaft. Relocate the bias terminal plates properly. Cleaning Roller 4 Is grease applied enough? No Remove and reapply conductive grease to Cleaning Roller shaft. Is the Transfer Corona dirty? Yes Clean each Corona Wire and housing. Transfer Corona 5 Is the Corona Wire broken? Yes Replace the Corona Wire. Is the Separation Corona dirty? Yes Clean each Corona Wire and housing. Separation Corona 6 Is the Corona Wire broken? Yes Replace the Corona Wire. HV Power Supply 7 Can you fix the problem if you replace the HV Power Supply? Yes OK