Code: 0150
Description: Backup memory read/write error (engine PWB)
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from 2 locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from 2 locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
Causes: The engine PWB EEPROM was improperly installed. Defective PWB. Defective EEPROM.
Remedy: The engine PWB EEPROM was improperly installed. 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Check that the EEPROM is peroperly installed on the engine PWB and reinstall it.
Defective PWB. Replace the engine PWB and check for correct operation.
Defective EEPROM. Check the EEPROM and if the data are currupted, contact the service support.
Defective PWB. Replace the engine PWB and check for correct operation.
Defective EEPROM. Check the EEPROM and if the data are currupted, contact the service support.