Code: 0840
Description: Faults of RTC
The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed.
The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed.
Causes: The battery is disconnected from the main PWB. Defective PWB.
Remedy: The battery is disconnected from the main PWB. 1. Make sure that the back-up batteries on the main PWB are not short-circuited. 2. Reset Maintenance T by executing U906. 3. If the same C call is displayed when power is switched on and off, replace the back up battery. 4. If communication error (due to a noise, etc.) is present with the RTC on the main circuit PWB, check the PWB is properly grounded.
Defective PWB. Replace the main PWB and check for correct operation.
Defective PWB. Replace the main PWB and check for correct operation.