Code: 2500
Description: Conveying motor 2 steadystate error
The rated speed signal detected the stability OFF continuously for 1 s after the conveying motor 2 stabilizes.
The rated speed signal detected the stability OFF continuously for 1 s after the conveying motor 2 stabilizes.
Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system. Defective motor. Defective PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Conveying motor 2 and video PWB (YC28)
Defective drive transmission system. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
Defective motor. Replace the Conveying motor 2.
Defective PWB. 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the video PWB and check for correct operation.
Defective drive transmission system. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
Defective motor. Replace the Conveying motor 2.
Defective PWB. 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the video PWB and check for correct operation.