Code: 3300
Description: Optical system (AGC) error
After AGC, correct input is not obtained at CCD.
After AGC, correct input is not obtained at CCD.
Causes: Defective connector cable or poor contact in the connector. Defective LED PWB or CCD PWB. Defective PWB.
Remedy: Defective connector cable or poor contact in the connector. 1. To check the lamp, execute U061 CCD. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. LED lamp PWB and ISC PWB (YC6) CCD PWB (YC2) and ISC PWB (YC9) ISC PWB (YC3) and Main PWB (YC11) 3. If the wiring is disconnected, shorted or grounded, replace the wiring.
Defective LED PWB or CCD PWB. If the LED lamp won’t light, replace the LED PWB and execut U411.
Defective PWB. 1. Replace the ISU and execute U411. 2. Replace the ISC PWB and execute U411. 3. Replace the main PWB.
Defective LED PWB or CCD PWB. If the LED lamp won’t light, replace the LED PWB and execut U411.
Defective PWB. 1. Replace the ISU and execute U411. 2. Replace the ISC PWB and execute U411. 3. Replace the main PWB.