Description: Document finisher backup error Read and write data does not match 3 times in succession.
Causes: DF main PWB
Remedy: 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF main PWB (YC7) and Engine PWB (YC33) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the DF main PWB