Mã lỗi C0350 — Kyocera TASKalfa 2552ci

Code: C0350

Description: Panel PWB communication error (Electronic volume I2C communication error)
Causes: Since NACK was received during the I2C communication, the retry was repeated 5 times and the initial command was transmitted, and then the retry was repeated 5 times again. After that, NACK was also received.
Remedy: 1 Resetting the main power The operation of the operation panel main PWB is faulty. Turn the power switch and the main power switch off . After 5s passes, turn the main power switch and the power switch on. 2 Checking the wire The wire is not properly connected to the operation panel main PWB. Reinsert the following wire connectors.• Operation panel PWB - Main PWB• Operation panel PWB - NFC PWB Electrical Diagram of PWBs 3 Replacing the wire The wire connecting to the operation panel main PWB is faulty. Replace the following wires if they are broken, short-circuited or have a ground fault.• Operation main PWB - Main PWB• Operation main PWB - NFC PWB Electrical Diagram of PWBs 4 Replacing the operation panel main PWB The operation panel main PWB is faulty. Replace the panel main PWB. Operation Panel Main PWB Replacement 5 Replacing the main PWB The main PWB is faulty. Replace the main PWB. Main PWB Replacement 6 Replacing the NFC PWB The NFC PWB is faulty. Replace the NFC PWB.

← Xem tất cả mã lỗi Kyocera TASKalfa 2552ci