Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C8140 — Kyocera TASKalfa 2552ci

Code: C8140

Description: DF tray motor error 1 Object: 4000-sheet finisher or 1000-sheet finisher
Causes: The DF tray sensor or the DF tray upper side sensor does not turn on after passing 30s when ascending the DF main tray or the DF tray.
Remedy: 1 Checking the DF main tray / DF tray The DF main tray / DF tray is not assembled properly. If the DF main tray/DF tray is not shifted manually vertically, repair the part that restricts the operation. 2 Checking the DF main tray / DF tray drive components The DF main tray / DF tray drive components are not properly attached, or they are faulty. Reattach the DF main tray / DF tray drive components. Then, replace them if they are not fixed. 3 Checking the wire The wire is not properly connected or is faulty. Reinsert the following wire connectors, and replace the wires there is no continuity.• DF tray motor - DF main PWB• DF tray sensor 4 - DF main PWBOr, • DF tray sensor 5 (with the folding unit) - DF main PWB Electrical Diagram of PWBs 4 Replacing the DF tray motor The DF tray motor is faulty. Replace the DF tray motor if it does not operate properly when checking the operation at U240. U240 Execution 5 (When installing the 1000- sheet finisher) Checking the wire The wire is not properly connected or is faulty. Reinsert the following wire connectors, and replace the wires when they have no continuity.• DF tray sensor 1 - DF main PWB• DF tray sensor 2 - DF main PWB Electrical Diagram of PWBs 6 (When installing the 4000- sheet finisher) Checking the wire The wire is not properly connected or is faulty. Reinsert the following wire connectors, and replace the wires when they have no continuity.• DF tray sensor 1 - DF main PWB• DF tray sensor 2 - DF main PWB Electrical Diagram of PWBs 7 Checking the wire The wire is not properly connected or is faulty. Reinsert the following wire connectors, and replace the wires when they have no continuity.• DF tray upper side sensor 1 - DF main PWB• DF tray upper side sensor 2 - DF main PWB Electrical Diagram of PWBs 8 Checking the wire The wire is not properly connected or is faulty. Reinsert the following wire connectors, and replace the wires when they have no continuity.• DF tray upper side sensor 1 - DF main PWB• DF tray upper side sensor 2 - DF main PWB Electrical Diagram of PWBs 9 (When installing the 1000- sheet finisher) Checking DF tray sensor 1 DF tray sensor 1 is not properly attached, or it is faulty. Reattach DF tray sensor 1 and execute U241 to check the operation. If it does not properly operate, replace the sensor. U241 Execution 10 (When installing the 4000- sheet finisher) Checking DF tray sensor 1, 2 DF tray sensors 1, 2 are not properly attached, or they are faulty. Reattach DF tray sensors 1, 2 and execute U241 to check the operation.If they do not properly operate, replace the sensors. U241 Execution 11 Checking DF tray upper side sensors 1, 2 DF tray upper surface sensors 1, 2 are not properly attached, or they are faulty. Reattach DF tray upper surface sensors 1, 2 and execute U241 to check the operation.If they do not properly operate, replace the sensors. U241 Execution 12 Replacing the DF main PWB The DF main PWB is faulty. Replace the DF main PWB. DF Main PWB Replacement

← Xem tất cả mã lỗi Kyocera TASKalfa 2552ci

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie