Description: LED failure detection Object: Dual scan DP
Causes: After 4 blocks of the LED lamps of the DPCIS are lit when turning on the power, the acquired peak value of some blocks is the reference value or less.
Remedy: 1 Checking the LED lamp The LED lamp of the DPCIS does not light. Execute U203 to confirm that the LED lamp of the DPCIS does not light. Go to the next step. U203 Execution 2 Checking the DPSHD PWB The DPSHD PWB is not properly connected. Reconnect the DPSHD PWB to the DPCIS. 3 Checking the wire The wire is not properly connected or is faulty. Reinsert the following wire connectors, and replace the wire when it has no continuity.• DPSHD PWB - DP main PWB Electrical Diagram of PWBs 4 Executing U411 DP scanning is not properly adjusted. Execute U411 [DP FD(ChartB)] and [DP FD(ChartA)]. U411 Execution 5 Replacing the DPCIS The DPCIS is faulty. Replace the DPCIS, and then execute U091 and U411. DP CIS Replacement 6 Replacing the DPSHD PWB The DPSHD PWB is faulty. Replace the DPSHD PWB.