Code: 2100
Description: Developing motor error
The developing motor ready input is not given for 5 s during the main motor is ON.
The developing motor ready input is not given for 5 s during the main motor is ON.
Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing motor. Defective developing motor. Defective engine PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Developing motor and engine PWB (YC14)
Defective drive transmission system of the developing motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective developing motor. Replace the developing motor.
Defective engine PWB. Replace the engine PWB and check for correct operation.
Defective drive transmission system of the developing motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective developing motor. Replace the developing motor.
Defective engine PWB. Replace the engine PWB and check for correct operation.