Code: C3210
Description: CIS lamp problem
When input value at the time of CIS illumination does not exceed the threshold value between 5 s.
When input value at the time of CIS illumination does not exceed the threshold value between 5 s.
Causes: Poor contact in the connector terminals.
Defective DP driver PWB
Defective DP inverter PWB.
Defective CIS.
Defective DP driver PWB
Defective DP inverter PWB.
Defective CIS.
Remedy: Poor contact in the connector terminals. Check the connection of connector on the ISM PWB and the connector on the DP driver PWB, and the continuity across the connector terminals. Repair or replace if necessary.
Defective DP driver PWB. Replace the DP driver PWB and check for correct operation.
Defective DP inverter PWB. Replace the DP inverter PWB and check for correct operation.
Defective CIS. Replace the CIS and check for correct operation.
Defective DP driver PWB. Replace the DP driver PWB and check for correct operation.
Defective DP inverter PWB. Replace the DP inverter PWB and check for correct operation.
Defective CIS. Replace the CIS and check for correct operation.