Code: 8260
Description: DF middle motor error
When the DF middle motor is driven, DF middle sensor does not turn on within 1s.
When the DF middle motor is driven, DF middle sensor does not turn on within 1s.
Causes: DF middle motor. DF middle sensor. DF main PWB.
Remedy: DF middle motor 1. Execute U240 Motor - Middle(L) to check the finisher operation. 2. Check that the drive from the motor reaches the middle roller. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF middle motor and DF main PWB (YC10) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the DF middle motor.
DF middle sensor 1. Execute U241 Finisher - Middle Tray Eject to check the finisher switch. 2. Check that the sensor and its mounting bracket are correctly positioned. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF middle sensor and DF main PWB (YC20) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the DF middle sensor.
DF main PWB Replace the DF main PWB (Refer to the service manual for the document finisher).
DF middle sensor 1. Execute U241 Finisher - Middle Tray Eject to check the finisher switch. 2. Check that the sensor and its mounting bracket are correctly positioned. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF middle sensor and DF main PWB (YC20) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the DF middle sensor.
DF main PWB Replace the DF main PWB (Refer to the service manual for the document finisher).