Mã lỗi 8100 — Kyocera TASKalfa 3011i

Code: 8100

Description: DF eject release motor error When the DF eject release motor is driven, DF bundle discharge sensor does not turn on within 1 s.
Causes: DF eject release motor DF bundle discharge unit sensor. DF bundle discharge unit sensor. DF main PWB
Remedy: DF eject release motor DF bundle discharge unit sensor 1. Execute U240 Motor - Eject Unlock (Full) to check the finisher operation. 2. Check that the eject guide of the process tray is opened and, if not, correct the guide. 3. Check that the drive from the motor reaches the eject guide. 4. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF bundle discharge unit sensor and DF main PWB (YC22)(3000-sheet finisher) DF bundle discharge unit sensor and DF main PWB (YC20)(1000-sheet finisher) 5. If the wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the DF eject release motor.
DF bundle discharge unit sensor 1. Execute U241 Finisher - Bundle Eject HP to check the finisher switch. 2. Check that the sensor and its mounting bracket are correctly positioned. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF bundle discharge unit sensor and DF main PWB (YC22)(3000-sheet finisher) DF bundle discharge unit sensor and DF main PWB (YC20)(1000-sheet finisher) 4. Replace the DF bundle eject unit sensor.
DF main PWB Replace the DF main PWB.

← Xem tất cả mã lỗi Kyocera TASKalfa 3011i

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie