Code: 3200
Description: Lamp error The white standard data obtained when the lamp is turned on at the time of an initialization is lower than the rated value.
Remedy: LED PWB Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LED PWB - CCD PWB (YC2) CCD PWB - Main PWB(YC2014): 30 ppm model - Engine PWB(YC5): 35/40 ppm models
Mirror Replace the image scanner carriage and execute U411 if the mirror is dropped off by drop shock.
CCD PWB Replace the image scanner carriage and execute U411.
Main PWB Replace the main PWB.
Engine PWB Replace the engine PWB.
Mirror Replace the image scanner carriage and execute U411 if the mirror is dropped off by drop shock.
CCD PWB Replace the image scanner carriage and execute U411.
Main PWB Replace the main PWB.
Engine PWB Replace the engine PWB.