Code: 8090
Description: DF paddle motor error In case the DF paddle sensor does not detect ON/ OFF when 1s passes while the DF paddle motor drives.
Remedy: DF paddle motor error 1. Execute [Motor] > [Beat] in U240 Checking the operation of the finisher. 2. Check if the paddle is rotating. 3. Check if the motor drive is delivered to the paddle. 4. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DF paddle motor - DF main PWB(YC9) 5. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 6. Replace the DF paddle motor.
DF paddle sensor 1. Execute [Finisher]>[Bundle Eject HP] in U241 Checking the operation of the finisher switch. 2. Check if there is a failure in the position of the sensor or mounting plate. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DF paddle sensor - DF main PWB(YC19) 4. Replace the DF paddle sensor.
DF main PWB Replace the DF main PWB.
DF paddle sensor 1. Execute [Finisher]>[Bundle Eject HP] in U241 Checking the operation of the finisher switch. 2. Check if there is a failure in the position of the sensor or mounting plate. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DF paddle sensor - DF main PWB(YC19) 4. Replace the DF paddle sensor.
DF main PWB Replace the DF main PWB.