Code: 8200
Description: DF side registration motor 2 error 2 In case JAM6910 (DF side registration sensor 2 stay jam) is detected twice in succession.
Remedy: DF side registration motor 2 1. Execute [Motor] > [Width Test] in U240 Checking the operation of the finisher. 2. Check if the side registration rear guide can be moved manually without being caught up. 3. Check if the motor drive is delivered to the side registration rear guide. 4. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DF side registration motor 2 - DF main PWB(YC9) 5. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 6. Replace the DF side registration motor 2.
DF side registration sensor 2 1. Execute [Finisher]>[Width Tail HP] in U241 Checking the operation of the finisher switch. 2. Check if there is a failure in the position of the sensor or mounting plate. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DF side registration sensor 2 - DF main PWB(YC19) 4. Replace the DF side registration sensor 2.
DF main PWB Replace the DF main PWB.
DF side registration sensor 2 1. Execute [Finisher]>[Width Tail HP] in U241 Checking the operation of the finisher switch. 2. Check if there is a failure in the position of the sensor or mounting plate. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DF side registration sensor 2 - DF main PWB(YC19) 4. Replace the DF side registration sensor 2.
DF main PWB Replace the DF main PWB.