Description: Communication error between the DP and SHD A communication error is detected. (35/40 ppm model only)
Remedy: DPSHD PWB 1. Execute the U906 Resetting the partial operation. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DPSHD PWB - DP main PWB 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 4. Replace the DPSHD PWB.