Code: 2500
Description: Transfer motor error
After transfer motor is driven, the ready signal does not turn to L within 2 s. After transfer motor is stabilized, the ready signal is at the H level for 1 s continuously
After transfer motor is driven, the ready signal does not turn to L within 2 s. After transfer motor is stabilized, the ready signal is at the H level for 1 s continuously
Causes: Defective connector cable or poor contact in the connector.
Defective drive transmission system of motor.
Defective fuser motor.
Defective engine PWB.
Defective drive transmission system of motor.
Defective fuser motor.
Defective engine PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Transfer motor and relay PWB (YC6) Relay PWB (YC5) and feed PWB 1 (YC13) Feed PWB 1 (YC1) and engine PWB (YC6)
Defective drive transmission system of motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective fuser motor. Replace the fuser motor.
Defective engine PWB. Replace the engine PWB and check for correct operation.
Defective drive transmission system of motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Defective fuser motor. Replace the fuser motor.
Defective engine PWB. Replace the engine PWB and check for correct operation.