Code: 3210
Description: CIS lamp error
When input value at the time of CIS illumination does not exceed the threshold value between 5 s.
When input value at the time of CIS illumination does not exceed the threshold value between 5 s.
Causes: Defective connector cable or poor contact in the connector.
Defective CIS.
Defective DPSHD PWB.
Defective DP relay PWB.
Defective CIS.
Defective DPSHD PWB.
Defective DP relay PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. CIS and DPSHD PWB (YC2) DPSHD PWB (YC3) and DP relay PWB (YC2)
Defective CIS. Replace the CIS and check for correct operation.
Defective DPSHD PWB. Replace the DPSHD PWB and check for correct operation.
Defective DP relay PWB. Replace the DP relay PWB and check for correct operation.
Defective CIS. Replace the CIS and check for correct operation.
Defective DPSHD PWB. Replace the DPSHD PWB and check for correct operation.
Defective DP relay PWB. Replace the DP relay PWB and check for correct operation.