Code: 3210
Description: CIS lamp error
When input value at the time of CIS illumination does not exceed the threshold value between 5 s.
When input value at the time of CIS illumination does not exceed the threshold value between 5 s.
Causes: CIS. DPSHD PWB. DP relay PWB.
Remedy: CIS 1. Execute U906 Separating Operation Release. 2. Execute CCD of U061 lamp check. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. CIS and DPSHD PWB (YC2) DPSHD PWB (YC3) and DP relay PWB (YC2) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the CIS and execute U091 and U411.
DPSHD PWB Replace the DPSHD PWB.
DP relay PWB Replace the DP relay PWB.
DPSHD PWB Replace the DPSHD PWB.
DP relay PWB Replace the DP relay PWB.