Mã lỗi 9050 — Kyocera TASKalfa 3501i

Code: 9050

Description: DP lift motor going down error
When the DP lift motor is driven, DP lift sensor 2 does not turn on within 1500 pulse. (Three recovery times.) The above has been detected 5 times.
Causes: DP lift motor. DP lift sensor 2. DP main PWB.
Remedy: DP lift motor 1. Execute U906 Separating Operation Release. 2. Execute U243 Lift Motor to check the DP motor operation. 3. Check that the original document lift guide can move downwards. 4. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DP lift motor and DP main PWB (YC5) If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the DP lift motor.
DP lift sensor 2 1. Execute U244 Lift L-Limit to check DP switch. 2. Confirm that the DP lift sensor 2 has been firmly fitted. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DP lift sensor 2 and DP main PWB (YC2) 4. Replace the DP lift sensor2.
DP main PWB Replace the DP main PWB