Code: 2201
Description: Drum motor CY steadystate error After motor is stabilized, the stable signal is turned OFF for continuous 2 s.
Causes:
Remedy: Drum unit C or Drum unit Y Check that the drum can be rotated by hand, and if it is locked, replace the drum unit C or drum unit Y. Defective connector cable or poor contact in the connector 1. Reinsert the connector. 2. Check continuity within the connector wire. If none, replace the wire. Drum motor CY and Engine relay PWB (YC13) Engine relay PWB (YC1) and Main/Engine PWB (YC4) Drive transmission system for the drum motor CY 1. Check if the couplings and gears rotate smoothly, and if not, clean or grease the gears. 2. Check broken couplings and gears, and replace if any. Drum motor CY Replace the drum motor CY. Engine relay PWB Replace the engine relay PWB. Main/Engine PWB Replace the Main/Engine PWB.