Code: 2610
Description: PF drive motor error (large capacity feeder)
After PF drive motor is driven, the ready signal does not turn to L within 2 s.
After PF drive motor is driven, the ready signal does not turn to L within 2 s.
Causes: PF drive motor. PF main PWB.
Remedy: PF drive motor 1. To check the feed unit operation, execute U247 LCF- Motor ON. 2. Check the paper feed roller and drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF drive motor and PF main PWB (YC16) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the PF drive motor.
PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).
PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).