Code: 3300
Description: Optical system (AGC) error
When the value of a gain becomes more than FF or 89 or less at least one at the AGC processing instruction execution time for CCD lamps.
When the value of a gain becomes more than FF or 89 or less at least one at the AGC processing instruction execution time for CCD lamps.
Causes: LED lamp PWB. CCD PWB. ISC PWB. Main PWB.
Remedy: LED lamp PWB 1. To check the lamp, execute U061 CCD. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. LED lamp PWB and ISC PWB (YC6) CCD PWB (YC2) and ISC PWB (YC9) ISC PWB (YC3) and Main PWB (YC11) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. If the LED lamp won’t light, replace the LED PWB and execut U411.
CCD PWB Replace the ISU and execute U411.
ISC PWB Replace the ISC PWB and execute U411.
Main PWB Replace the main PWB.
CCD PWB Replace the ISU and execute U411.
ISC PWB Replace the ISC PWB and execute U411.
Main PWB Replace the main PWB.