Code: 8090
Description: DF paddle motor error
When the DF paddle motor is driven, DF paddle sensor does not turn on within 1 s.
When the DF paddle motor is driven, DF paddle sensor does not turn on within 1 s.
Causes: DF paddle motor. DF paddle sensor. DF main PWB.
Remedy: DF paddle motor 1. Execute U240 Motor - Beat to check the finisher operation. 2. Check that the paddle can rotate. 3. Check that the drive from the motor reaches the paddle. 4. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF paddle motor and DF main PWB (YC15) (3000-sheet finisher) DF paddle motor and DF main PWB (YC11) (1000-sheet finisher) 5. If the wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the DF paddle motor.
DF paddle sensor 1. Execute U241 Finisher - Bundle Eject HP to check the finisher switch. 2. Check that the sensor and its mounting bracket are correctly positioned. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF paddle sensor and DF main PWB (YC22) (3000-sheet finisher) DF paddle sensor and DF main PWB (YC20) (1000-sheet finisher) 4. Replace the DF paddle sensor.
DF main PWB Replace the DF main PWB (Refer to the service manual for the document finisher).
DF paddle sensor 1. Execute U241 Finisher - Bundle Eject HP to check the finisher switch. 2. Check that the sensor and its mounting bracket are correctly positioned. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF paddle sensor and DF main PWB (YC22) (3000-sheet finisher) DF paddle sensor and DF main PWB (YC20) (1000-sheet finisher) 4. Replace the DF paddle sensor.
DF main PWB Replace the DF main PWB (Refer to the service manual for the document finisher).