Mã lỗi 9040 — Kyocera TASKalfa 3510i

Code: 9040

Description: DP lift motor going up error
When the DP lift motor is driven, DP lift sensor 1 does not turn on within 1500 pulse. (Three recovery times.) The above has been detected 5 times. * The number of detection should be weighted with one for the rise at job start and two for the irregular rise during transpoting. The accumulated number must be cleared at completion of a normal rise. The default threshold is 5.
Causes: DP lift motor. DP lift sensor 1. DP main PWB.
Remedy: DP lift motor 1. Execute U906 Separating Operation Release. 2. Execute U243 Lift Motor to check the DP motor operation. 3. Check that the original document lift guide can move upwards. 4. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DP lift motor and DP main PWB (YC5) 5. If the wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the DP lift motor.
DP lift sensor 1 1. Execute U244 Lift L-Limit to check DP switch. 2. Check that the sensor and its mounting bracket are correctly positioned. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DP lift sensor 1 and DP main PWB (YC4) 4. Replace the DP lift sensor 1.
DP main PWB Replace the DP main PWB