Causes: The input data did not exceed threshold for 5s when lighting the CIS lamp.
Remedy: 1 Releasing the partial operation The partial operation is executed. Execute resetting the partial operation at U906. U906 Execution 2 Checking the DPCIS The CIS lamp does not light. Check if the CIS lamp lights by executing U061 [CIS]. If it does not light, replace the DPCIS and execute U091 and U411. DP CIS Replacement 3 Cleaning the CIS glass and the CIS roller The CIS glass or the CIS roller is dirty. Clean the CIS glass and the CIS roller. 4 Checking the DPSHD PWB The DPSHD PWB is not properly connected. Reconnect the DPSHD PWB to the DPCIS. 5 Checking the wire The wire is not properly connected or is faulty. Reinsert the following wire connectors, and replace the wires when they have no continuity.• DPSHD PWB - DP main PWB• DP main PWB - Engine PWB Electrical Diagram of PWBs 6 Firmware upgrade The firmware is faulty. Upgrade the engine firmware to the latest version Firmware Upgrade 7 Replacing the DPSHD PWB The DPSHD PWB is faulty. Replace the DPSHD PWB. 8 Replacing the DP main PWB The DP main PWB is faulty. Replace the DP main PWB. DP Main PWB Replacement 9 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. Engine PWB Replacement