Code: 0840
Description: Faults of RTC [Check at powerup] The RTC setting has reverted to a previous state. Or, the machine has not been turned on for 5 years (regularly compared with a set value stored in the EEPROM). The RTC setting is older than 00:01 on January 1, 2000. [Checked periodically (at every 5 minutes) after powerup.] The RTC setting has reverted to a state older than the last time it was checked. 10 minutes have been passed since the previous check.
Remedy: Settings of RTC: Execute Date Setting using the system menu.
Backup battery (Main PWB): 1. Check if the backup battery on the main PWB is not short-circuited. 2. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. If the same service call error is displayed, replace the backup battery.
Main PWB: 1. If the communication error (due to a noise, etc.) is present with the RTC on the main PWB, check that the PWB is properly grounded or secured by screws. 2. Replace the main PWB.
Backup battery (Main PWB): 1. Check if the backup battery on the main PWB is not short-circuited. 2. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. If the same service call error is displayed, replace the backup battery.
Main PWB: 1. If the communication error (due to a noise, etc.) is present with the RTC on the main PWB, check that the PWB is properly grounded or secured by screws. 2. Replace the main PWB.