Description: Drum motor BK startup error After the motor starting, the stable signal is not turned ON within 2 s.
Remedy: Drum unit BK Check that the drum can be rotated by hand, and if it is locked, replace the drum unit BK. Defective connector cable or poor contact in the connector 1. Reconnect the connector if its connection is loose. 2. Check the continuity within the connector wire. If none, replace the wire. Drum motor BK - Engine PWB(YC16): 30 ppm model - Engine PWB(YC23): 35/40 ppm models Drum Drive transmission system for the drum motor BK 1. Check if the couplings and gears rotate smoothly, and if not, clean or grease the gears. 2. Check for broken couplings and gears, and replace if any are found. Drum motor BK Replace the drum motor BK. Engine PWB Replace the engine PWB.