Code: 2820
Description: Transfer motor steadystate error After the motor is stabilized, the ready signal is turned OFF for continuous 1 s.
Remedy: Primary transfer unit 1. Check that the belt can be rotated by hand, and if it is locked, check for foreign objects such as jammed paper, and if jammed, remove it. 2. Replace the primary transfer unit.
Defective connector cable or poor contact in the connector 1. Reconnect the connector if its connection is loose. 2. Check the continuity within the connector wire. If none, replace the wire. Transfer motor - Engine PWB(YC15): 30 ppm model - Engine PWB(YC22): 35/40 ppm models
Drive transmission system for the transfer motor 1. Check if the rollers and gears rotate smoothly. If not, clean or grease the bushes and gears. 2. Check for broken gears and replace if any are found.
Transfer motor Replace the transfer motor.
Engine PWB Replace the engine PWB.
Defective connector cable or poor contact in the connector 1. Reconnect the connector if its connection is loose. 2. Check the continuity within the connector wire. If none, replace the wire. Transfer motor - Engine PWB(YC15): 30 ppm model - Engine PWB(YC22): 35/40 ppm models
Drive transmission system for the transfer motor 1. Check if the rollers and gears rotate smoothly. If not, clean or grease the bushes and gears. 2. Check for broken gears and replace if any are found.
Transfer motor Replace the transfer motor.
Engine PWB Replace the engine PWB.