Code: 8100
Description: DF eject release motor error The DF bundle eject sensor does not detect ON/ OFF when 1s passes while the DF eject release motor drives.
Remedy: DF eject release motor 1. Execute [Motor] > [Eject Unlock (Full)] in U240 Checking the operation of the finisher. 2. Check if the eject guide of the finisher tray is open and otherwise, correct it. 3. Check if the motor drive is delivered to the eject guide. 4. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DF eject release motor - DF main PWB(YC8) 5. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 6. Replace the DF eject release motor.
DF bundle eject sensor 1. Execute [Finisher]>[Bundle Eject HP] in U241 Checking the operation of the finisher switch. 2. Check if there is a failure in the position of the sensor or mounting plate. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DF bundle eject sensor - DF main PWB(YC19) 4. Replace the DF bundled paper eject sensor.
DF main PWB Replace the DF main PWB.
DF bundle eject sensor 1. Execute [Finisher]>[Bundle Eject HP] in U241 Checking the operation of the finisher switch. 2. Check if there is a failure in the position of the sensor or mounting plate. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DF bundle eject sensor - DF main PWB(YC19) 4. Replace the DF bundled paper eject sensor.
DF main PWB Replace the DF main PWB.