Code: 8410
Description: Punch slide motor error 1 In case the punch slide sensor is not turned ON when the home position has moved 60mm. (35/40 ppm model only)
Remedy: Punch slide motor 1. Execute [Motor] > [Punch Move] in U240 Checking the operation of the finisher. 2. The punch slide section of the punch unit moves back and forth manually without being caught. 3. Check if the motor drive is delivered to the punch section. 4. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Punch slide motor - Punch PWB (YC3) 5. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 6. Replace the punch slide motor.
Punch slide sensor 1. Execute [Punch] > [Punch HP] in U241 Checking the operation of the finisher switch. 2. Check if there is a failure in the position of the sensor or mounting plate. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Punch slide sensor - Punch PWB (YC6) 4. Replace the punch slide sensor.
Punch PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Punch PWB - DF main PWB (YC7) 2. Replace the Punch PWB.
DF main PWB Replace the DF main PWB.
Punch slide sensor 1. Execute [Punch] > [Punch HP] in U241 Checking the operation of the finisher switch. 2. Check if there is a failure in the position of the sensor or mounting plate. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Punch slide sensor - Punch PWB (YC6) 4. Replace the punch slide sensor.
Punch PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Punch PWB - DF main PWB (YC7) 2. Replace the Punch PWB.
DF main PWB Replace the DF main PWB.